simple operation
management via MEMO programmer
power supply 12…24V AC or DC
relay NO-type
power supply: | 12…24V AC/DC ±10% |
max current consumption: | 30mA (relay on) |
memory: | 200 remote controls with an individual number in memory. Cooperation with DTM868MHz remote controls. |
operating temperature: | -20°C /+55°C |
external case dimensions (width depth height): | 50 (71 with mounting brackets)x42x23mm |
mounting: | receiver for indoor or inside other automation enclosure mounting, IP-20 |
relay outputs | |
(type, number, maximum load): | NO / 1 / 1A (24V AC / DC) |
output mode: | monostable, turn-on time 1s |
radio module: | modern, digital, superheterodyne with intelligent adaptation to external radio conditions, high reliability, repeatability and optimum sensitivity |
transmition safety: | 104-bit IRS |
modulation / frequency: | FSK / 868MHz |
input impedance of antenna: | 50Ω |
antenna: | terminals for connecting an external antenna |
user interface: | clear and simple one-button user interface with built-in LED |
remote configuration: | the ability to assign any remote control button to the receiver |
deleting a single remote: | remote control presence needed |
possibility to add the remote without access to receiver button: | easy remote control adding function with the ability to lock and unlock the function, Galactic function – allows adding remotes programmed and configured outside the installation |
management of the receiver: | using receiver button and by connecting MEMO programmer |
verification of remote controls in memory: | function showing the number of added remote controls |